The SpotFlash is a compact and complete solution for all purifications and separations by flash chromatography. The system is constituted by a 25bars pump, a controller, a fraction collector with a capacity of 2 racks of 44 tubes 35ml, a column holder and a UV detection (with filters or spectrophotometer 190-750nm). Different flow rates are available from 100 to 500ml/min in isocratic, binary or quaternary versions with the possibility to make elution gradient to optimize the separations. The spotFlash is enterely controlled by a PC with touch screen and the software Armen Glider Flash.This compact system is a fully automated solution for fast and reliable separations. Pump dimensions 675x580x570mm.  
 
Reference Description Flow rate ml/min Pressure limit, bars Wavelenght nm SU Price
Spot system, isocratic pump, PC, fraction collector, Filters UV detector 0-100 25 200, 220, 254, 280 1
Spot system, isocratic pump, PC, fraction collector, Filters UV detector 0-200 25 200, 220, 254, 280 1
Spot system, isocratic pump, PC, fraction collector, Filters UV detector 0-300 25 200, 220, 254, 280 1
Spot system, binary pump, PC, fraction collector, Filters UV detector 0-100 25 200, 220, 254, 280 1
Spot system, binary pump, PC, fraction collector, Filters UV detector 0-200 25 200, 220, 254, 280 1
Spot system, binary pump, PC, fraction collector, Filters UV detector 0-300 25 200, 220, 254, 280 1
Spot system, quaternary pump, PC, fraction collector, Filters UV detector 0-100 25 200, 220, 254, 280 1
Spot system, quaternary pump, PC, fraction collector, Filters UV detector 0-200 25 200, 220, 254, 280 1
Spot system, quaternary pump, PC, fraction collector, Filters UV detector 0-300 25 200, 220, 254, 280 1
Spot system, isocratic pump, PC, fraction collector, PC, fraction collector, UV detector single 0-100 25 190-740 1
Spot system, isocratic pump, PC, fraction collector, PC, fraction collector, UV detector single 0-200 25 190-740 1
Spot system, isocratic pump, PC, fraction collector, UV detector single 0-300 25 190-740 1
Spot system, binary pump, PC, fraction collector, UV detector single 0-100 25 190-740 1
Spot system, binary pump, PC, fraction collector, UV detector single 0-200 25 190-740 1
Spot system, binary pump, PC, fraction collector, UV detector single 0-300 25 190-740 1
Spot system, quaternary pump, PC, fraction collector, UV detector single 0-100 25 190-740 1
Spot system, quaternary pump, PC, fraction collector, UV detector single 0-200 25 190-740 1
Spot system, quaternary pump, PC, fraction collector, UV detector single 0-300 25 190-740 1
Spot system, isocratic pump, PC, fraction collector, UV detector double 0-100 25 190-740 1
Spot system, isocratic pump, PC, fraction collector, UV detector double 0-200 25 190-740 1
Spot system, isocratic pump, PC, fraction collector, UV detector double 0-300 25 190-740 1
Spot system, binary pump, PC, fraction collector, UV detector double 0-100 25 190-740 1
Spot system, binary pump, PC, fraction collector, UV detector double 0-200 25 190-740 1
Spot system, binary pump, PC, fraction collector, UV detector double 0-300 25 190-740 1
Spot system, quaternary pump, PC, fraction collector, UV detector double 0-100 25 190-740 1
Spot system, quaternary pump, PC, fraction collector, UV detector double 0-200 25 190-740 1
Spot system, quaternary pump, PC, fraction collector, UV detector double 0-300 25 190-740 1
 
 
 
 
Sales conditionsTechnical specificationsQuality policy