Indicators for autoclaves

H2O2 indicator strip

Discover
• For monitoring hydrogen peroxide sterilisation processes (using 2.3 mg/l vH2O2 at 50 °C for 6 minutes)
• Free of lead and toxic heavy metals
• Indicator changes from brown to green
• Dimensions 19 x 70 mm

Excelsior dry heat indicators

Discover
For dry heat sterilisation control.

Autoclave tape

Discover
• 4 Self-adhesive
• Roll 19 mm x 50 m
• For steam sterilization between 121 and 134 °C
• The tape changes colour when sterilization is complete

Indicator tape for sterilisation

Discover
Adhesive indicator tape to put on items before sterilisation. Temperature sensitive ink gradually changes colour when the desired temperature has been reached. 3 models of indicator tape are available: for the autoclave (damp heat), any type of dry heat sterilisation and gas (ethylene oxide). Dispensers 086000 and 140265 are suitable for use with the tape.

Adhesive tape for autoclave

Discover
Adhesive tape for the sealing of containers or packaging of products intended for autoclave. Do not have a sterilisation indicator.

Sterilization and wash indicators

Discover
• Non-sequential integrator
• Declination according to autoclave cycles:
- TST SKC short cycle: 121 °C/15 min

- TST 3702 standard cycle: 125 °C/20 min

Pack Bowie-Dick Browne

Discover
Bowie-Dick type ready to use test packet for steam sterilisers. Indicator to be used in specific tests as defined in EN 867-1 Class B 867-4 and in the norm ISO 11140 Class 2.

Instructions: Place the test at the centre of the top shelf and carry out a BD cycle. Open the package and check sheet: the successful test is blue, another colour indicates failure.

Emulator Prion 134-18 NS

Discover
The emulator Prion 134-18 NS is a class 6 multi-parameter indicator (temperature, time and saturated steam). It is used during steam sterilisation, cycle Prion 134 °C / 18 minutes.

Excelior sterilisation indicator

Discover
For steam sterilisation control

Steripoint sterilisation indicator

Discover
• High accuracy in the shift time
• Constant reproducibility
• Quality commitment due to the numerous controls of shift times during production
• The shift of Steripoint® is inhibited by the presence of a steam / air or gas mixture, or when one of the parameters of the cycle is insufficient
• The shift from purple to green ink indicates compliance of time, temperature and steam conditions during sterilisation cycles

Bio indicator STERIKON

Discover
• 2 ml ampoule of Geobacillus stearothermophilus ATCC 7953 spores
• Spore completely destroyed after autoclaving (121 °C / 15 min)
• After incubation:
if yellow/orange bulb: poor autoclaving
if red/purple bulb: correct autoclaving

GST sterilisation indicator

Discover
• Ampoule 4 ml
• Spore bacillus Geobacillus stearothermophilus
• For sterilisation control (121 °C / 20 minutes)
• Easy to use
• After autoclaving, the ampoule is placed in an incubator at 55 - 60 °C for 24 - 48 hours
• If colour change compared to a control: sterilisation did not work